Category 04 · 56 supplier records

Data center cooling companies

Compare data center cooling companies by the part of the thermal system they publish. Match air cooling, direct-to-chip cooling, immersion and coolant distribution to the facility loop, heat rejection and service package.

Latest supplier evidence 2 October 2026

Choose the buying scope

Compare the right responsibilities.

Use these package boundaries to decide what belongs in your shortlist and what evidence to request.

Air cooling, chillers & heat rejection

Compare room, row and rack cooling with the chilled-water and outdoor heat-rejection equipment it depends on.

Before you request a quote

Specify thermal duty, ambient conditions, supply temperatures, water assumptions, resilience and the measurement boundary.

Direct-to-chip liquid cooling

Use explicit published cold-plate or direct-to-chip scope when comparing suppliers for CPU and GPU cooling.

Before you request a quote

Confirm server compatibility, coolant, pressure and flow, facility-loop interfaces, leak response and acceptance testing.

Coolant distribution units (CDUs)

Separate the CDU package from cold plates, rack distribution, facility water and heat rejection.

Before you request a quote

Compare rated duty at your operating conditions, loop separation, redundancy, controls, water quality and service access.

Immersion cooling companies

Include immersion only where the supplier publishes that system scope; a liquid-cooling claim alone does not establish it.

Before you request a quote

Request hardware and fluid compatibility, tank and lifting arrangements, maintenance procedures and lifecycle responsibilities.

Cooling commissioning & maintenance

Check installation, commissioning, controls integration, planned maintenance and retrofit support separately from product supply.

Before you request a quote

Agree acceptance tests, control sequences, spares, response coverage, training and operating handover.

Published scope · Unclaimed records

Compare suppliers in the US and UK.

These examples illustrate different published offerings; they are not a ranking or a complete shortlist. A company may cover several packages. Explore every category record below or use the directory filters.

Directory coverage and evidence

Cooling, Liquid Cooling & Water covers chillers, precision cooling, CDUs, heat rejection, water systems and thermal controls. The directory lists 56 supplier records in this category, including Vertiv, Airedale by Modine, STULZ UK and Munters. Launch-market assignments are United States (39) and United Kingdom (17). Marketed coverage labels include United States, United Kingdom, United States and global delivery and United States & global. Listed records map to the Site & Plan, Connect & Power, Design & Build, Fit Out & Commission, Operate & Maintain and Upgrade & Exit project stages.

Launch-market assignments help you discover suppliers. They do not establish a delivery territory, current capacity or project fit. Published coverage and specifications need confirmation for your project.

US launch-market comparison

US data center cooling companies

Browse all 39 US records
US data center cooling companies: selected published offerings, marketed coverage and first-party evidence. Unclaimed editorial records.
Supplier & comparison focusSelected published scopeCoverage & evidence
TraneUnclaimedAir cooling, chillers & heat rejectionRFQ questions
  • Air- and water-cooled data-centre chillers
  • Computer-room air handlers
  • Commissioning and retrofit services

Air-cooled chiller scalePublishes the Ascend air-cooled data-centre chiller with capacity up to 2 MW, integrated free cooling and zero-water-waste positioning.Published specification

United States & North America

Record checked

AccelsiusUnclaimedDirect-to-chip liquid coolingRFQ questions
  • NeuCool two-phase direct-to-chip cooling
  • CPU and GPU cold-plate cooling

United States & North America

Record checked

Motivair by Schneider ElectricUnclaimedCoolant distribution units (CDUs)RFQ questions
  • Coolant distribution units
  • ChilledDoor rack cooling systems
  • Dynamic cold plates

United States & global

Record checked

LiquidStackUnclaimedImmersion cooling companiesRFQ questions
  • Immersion liquid cooling
  • Direct-to-chip liquid cooling
  • GigaModular CDU platform

Published GigaModular capacityLiquidStack states that the GigaModular CDU platform supports multi-megawatt building blocks that scale deployments up to 14 MW.Published specification

United States & global

Record checked

UK launch-market comparison

UK data centre cooling companies

Browse all 17 UK records
UK data centre cooling companies: selected published offerings, marketed coverage and first-party evidence. Unclaimed editorial records.
Supplier & comparison focusSelected published scopeCoverage & evidence
Airedale by ModineUnclaimedAir cooling, chillers & heat rejectionRFQ questions
  • Data-centre chillers
  • Precision cooling systems
  • Commissioning and integrated systems testing

Published operating conditionsThe TurboChill DCS Stainless Steel page publishes supply-water temperatures up to 26°C and operation at ambient temperatures up to 55°C, with unit excursion testing completed to 62°C.Published specification

UK & global

Record checked

MuntersUnclaimedCoolant distribution units (CDUs)RFQ questions
  • Coolant distribution units
  • CRAH/CRAC fan walls
  • Dry coolers

UK & global

Record checked

VertivUnclaimedAir cooling, chillers & heat rejectionRFQ questions
  • Liquid-cooling systems and services
  • Chillers and heat-rejection systems
  • Room, row and rack cooling

AI-ready cooler rangeThe EMEA product portfolio lists the CoolLoop Trim Cooler with an 850 to 3,000 kW range.Published specification

UK & EMEA

Record checked

STULZ UKUnclaimedCooling commissioning & maintenanceRFQ questions
  • Liquid-cooling solutions
  • Service contracts
  • Planned preventative maintenance

UK-wide

Record checked

Relevant project stages
Where this capability enters the delivery lifecycle.
Procurement guide
Define the cooling package before comparing offers
Align the thermal duty, interfaces, measurement boundary, water plan and acceptance evidence.
Q4 2026 lead-time report
Transformer and generator lead times in the UK and Europe
Sourced lead times for transformers, HV/MV switchgear, standby generators, UPS and cooling, with named directory suppliers.

From the directory records

Common questions

How do I compare data center cooling companies?

Compare the same thermal duty, rack-density assumptions, operating temperatures, ambient conditions, resilience and system boundary. Identify who supplies the IT-side equipment, coolant distribution, facility loop, heat rejection, controls and lifecycle support. Request performance and acceptance evidence for your proposed operating conditions.

Does a liquid-cooling supplier also provide immersion or CDUs?

Check the published product scope. Direct-to-chip systems, immersion systems, coolant distribution units and facility cooling are separate packages, even when one supplier offers several. The comparison shows only selected offerings already documented in each supplier record.

How many suppliers does the directory list for cooling, liquid cooling & water?

The directory currently lists 56 unclaimed supplier records in Cooling, Liquid Cooling & Water.

Who supplies cooling, liquid cooling & water for data-centre and grid projects in the United States?

The directory lists 39 supplier records for Cooling, Liquid Cooling & Water with a United States launch-market assignment, including Trane, Motivair by Schneider Electric, Accelsius and LiquidStack. Coverage is supplier-published and should be confirmed directly.

Who supplies cooling, liquid cooling & water for data-centre and grid projects in the United Kingdom?

The directory lists 17 supplier records for Cooling, Liquid Cooling & Water with a United Kingdom launch-market assignment, including Vertiv, Airedale by Modine, STULZ UK and Munters. Coverage is supplier-published and should be confirmed directly.

Supplier discovery · Unclaimed records

All 56 category records

Search & filter
Explore by market
United States39United Kingdom17

Coverage is supplier-published. Confirm project fit directly.